DATA CENTER LIQUID COOLING HOSE
HIGH WEAR RESISTANT · UV / OZONE RESISTANT · 1 or 2 layers of synthetic fiber braid · 13.8 bar working / 55 bar burst
- Published Range
- Nominal bore:6.1–32.8 mm
- Max working pressure:13.8 bar
- Min burst pressure:55 bar
- Mass per metre:0.13–0.7 kg/m.
- Hose Features
- Bend Radius:Minimum bend radius 24.5–195 mm .
- Inner Tube:Black EPDM synthetic rubber
- Reinforcement:1 or 2 layers of synthetic fiber braid reinforcement
- Cover:Black EPDM synthetic rubber with weather, abrasion, ozone resistance, and V0 flame retardancy
- Application:DATA CENTER LIQUID COOLING HOSE — Data Center Liquid Cooling Hose — full specification table, PDF datasheet and factory-direct supply.
24 Hours Service Hotline
+86 137 2136 0724






Data Display
DATA CENTER LIQUID COOLING HOSE — Data Center Liquid Cooling Hose — full specification table, PDF datasheet and factory-direct supply.
| SPECIFICATION (inch) | HOSE INNER DIAMETER (I.D)mm (min) | HOSE INNER DIAMETER (I.D)mm (max) | HOSE OUTER DIAMETER (O.D)mm (min) | HOSE OUTER DIAMETER (O.D)mm (max) | MAXIMUM WORKING PRESSURE Max.W.P (MPa) (MPa) | psi | MINIMUM BURST PRESSURE Min.B.P (MPa) (MPa) | psi | MINIMUM BENDING RADIUS Min.B.R (mm) (mm) | REFERENCE WEIGHT W.T (kg/m) (kg/m) |
|---|---|---|---|---|---|---|---|---|---|---|
| 1/4" | 6.1 | 7.2 | 11.6 | 12.6 | 1.38 | 200 | 5.5 | 798 | 24.5 | 0.13 |
| 5/16" | 7.7 | 8.3 | 14.5 | 15.5 | 1.38 | 200 | 5.5 | 798 | 31.5 | 0.18 |
| 3/8" | 9.5 | 10.3 | 15.4 | 16.4 | 1.38 | 200 | 5.5 | 798 | 37 | 0.19 |
| 1/2" | 12.5 | 13.3 | 19.7 | 20.7 | 1 | 145 | 1 | 145 | 69 | 0.25 |
| 5/8" | 15.8 | 16.6 | 22.5 | 23.7 | 1 | 145 | 1 | 145 | 88 | 0.30 |
| 3/4" | 18.8 | 19.6 | 26.4 | 27.6 | 1 | 145 | 1 | 145 | 113 | 0.35 |
| 1" | 25.2 | 26.2 | 33.6 | 34.8 | 1 | 145 | 1 | 145 | 143 | 0.52 |
| 1 1/4" | 31.8 | 32.8 | 43 | 44.6 | 1 | 145 | 1 | 145 | 195 | 0.70 |
Values are reproduced from the official YIBO product page. psi columns = MPa × 145.038, rounded. Ratings run to 13.8 bar working / 55 bar minimum burst over the 6.1–32.8 mm bore band; the order data sheet governs the batch.
Application & Selection
DATA CENTER LIQUID COOLING HOSE — Data Center Liquid Cooling Hose — full specification table, PDF datasheet and factory-direct supply. DATA CENTER LIQUID COOLING HOSE covers 6.1–32.8 mm across 8 published codes.
DATA CENTER LIQUID COOLING HOSE tops out at 13.8 bar working over its 8 codes. This series weighs 0.13–0.7 kg/m. Assemblies are crimped and pressure-tested in-house, metric / BSP / JIC / ORFS ends, across the 8 codes in the 6.1–32.8 mm band. Smallest order of DATA CENTER LIQUID COOLING HOSE: 100 m, covering its 8 codes.
Frequently Asked Questions
What bore sizes does DATA CENTER LIQUID COOLING HOSE cover?
DATA CENTER LIQUID COOLING HOSE is published in 8 codes spanning 6.1–31.8 mm nominal bore, from 1/4" upward. 8 codes, 6.1–32.8 mm bore at 0.13–0.7 kg/m, all taken from the table.
What is the working pressure of DATA CENTER LIQUID COOLING HOSE?
DATA CENTER LIQUID COOLING HOSE tops out at 13.8 bar working over its 8 codes. Sizing: read the 8 rows over 6.1–32.8 mm against your own circuit rather than the range maximum.
What is the minimum order quantity for DATA CENTER LIQUID COOLING HOSE?
The minimum on standard DATA CENTER LIQUID COOLING HOSE is 100 m and it applies to every code in the 6.1–31.8 mm band. Cut a free sample of DATA CENTER LIQUID COOLING HOSE from the production run before committing to volume.
What is the production lead time on DATA CENTER LIQUID COOLING HOSE, and can it carry our brand?
Lead time for DATA CENTER LIQUID COOLING HOSE is around 20 days from order confirmation depending on quantity, and it covers every code in the 6.1–31.8 mm band. Assemblies are crimped and pressure-tested in-house, metric / BSP / JIC / ORFS ends, across the 8 codes in the 6.1–32.8 mm band.
Get a quote
Please fill out the form below and we will contact you within 24 hours.
We are online 24/7!
We will contact you within half an hour of receiving your enquiry.
Hotline